HOME > Á¦Ç°¼Ò°³ > 1CH > PW-1000

INPUT SELECT
(110V / 220V)
DC OUTPUT
MODEL
VOLT
AMP
SWITCH
+5
200
PW-1000A
SWITCH
+12
83
PW-1000B
SWITCH
+15
66
PW-1000C
SWITCH
+24
42
PW-1000D
SWITCH
+48
21
PW-1000F
-
OTHER VOLT
CUSTOM-MADE

DIMENSION (L¡¿W¡¿H) §®
310 ¡¿ 130 ¡¿ 190
WEIGHT (§¸)
5.3
 
Commom Specification
INPUT CONDITIONS
INPUT VOLTAGE
Vac
90 to 130 / 180 to 260
INPUT CURRENT
Aac
Max 12.6
FREQUENCY
Hz
47 to 63
EFFICIENCY
%
Min. 72
INRUSH CURRENT
A
Max. 45
OUT CONDITIONS
OUTPUT VOLT ADJ
%
¡¾ 5
LINE REGULATION
%
¡¾ 1
LOAD REGULATION
%
¡¾ 1
OVER VOLTAGE
-
SHUT DOWN METHOD MANUAL RESET
OVER CURRENT
-
CONSTANT CURRENT LIMITING WITH AUTO RECOVERY
HOLD UP TIME
§Â
Min. 20
PEAK OUTPUT
%
Max. 110
RIPPLE & NOISE
mV p-p
1% + 50
Enduring Voltage & Isolation
INPUT ¢¢ F.G (Chassis)
Vac
1,500 for 1Minute (Nominal Temperature and Humidity)
INPUT ¢¢ OUTPUT
Vac
1,500 for 1Minute (Nominal Temperature and Humidity)
OUTPUT ¢¢ F.G
Vac
1,500 for 1Minute (Nominal Temperature and Humidity)
INPUT ¢¢ OUTPUT ¢¢ F.G
M§Ù
Min 100 Up (500Vdc Insulation Tester)
Operating Condition
OPERATING TEMPERATURE
¡É
-10 ~ +50
COOLING METHOD
-
Nature Cooling & Air Fan
STORAGE TEMPERATURE
¡É
-20 ~ +80
HUMIDITY
%
10 ~ 90 RH
VIBRATION
10 ~ 55Hz at 1G, 3 Minutes period, 30 Minutes along X, Y and Z axis
IMPACT
10G for 20ms once on each X, Y and Z axis
SAFETY
SAFETY APPROVED
-
EMI & EMS
-