HOME > ǰҰ > 1CH > PW-1000

INPUT SELECT
(110V / 220V)
DC OUTPUT
MODEL
VOLT
AMP
SWITCH
+5
200
PW-1000A
SWITCH
+12
83
PW-1000B
SWITCH
+15
66
PW-1000C
SWITCH
+24
42
PW-1000D
SWITCH
+48
21
PW-1000F
-
OTHER VOLT
CUSTOM-MADE

DIMENSION (LWH)
310 130 190
WEIGHT ()
5.3
 
Commom Specification
INPUT CONDITIONS
INPUT VOLTAGE
Vac
90 to 130 / 180 to 260
INPUT CURRENT
Aac
Max 12.6
FREQUENCY
Hz
47 to 63
EFFICIENCY
%
Min. 72
INRUSH CURRENT
A
Max. 45
OUT CONDITIONS
OUTPUT VOLT ADJ
%
5
LINE REGULATION
%
1
LOAD REGULATION
%
1
OVER VOLTAGE
-
SHUT DOWN METHOD MANUAL RESET
OVER CURRENT
-
CONSTANT CURRENT LIMITING WITH AUTO RECOVERY
HOLD UP TIME
Min. 20
PEAK OUTPUT
%
Max. 110
RIPPLE & NOISE
mV p-p
1% + 50
Enduring Voltage & Isolation
INPUT F.G (Chassis)
Vac
1,500 for 1Minute (Nominal Temperature and Humidity)
INPUT OUTPUT
Vac
1,500 for 1Minute (Nominal Temperature and Humidity)
OUTPUT F.G
Vac
1,500 for 1Minute (Nominal Temperature and Humidity)
INPUT OUTPUT F.G
M
Min 100 Up (500Vdc Insulation Tester)
Operating Condition
OPERATING TEMPERATURE
-10 ~ +50
COOLING METHOD
-
Nature Cooling & Air Fan
STORAGE TEMPERATURE
-20 ~ +80
HUMIDITY
%
10 ~ 90 RH
VIBRATION
10 ~ 55Hz at 1G, 3 Minutes period, 30 Minutes along X, Y and Z axis
IMPACT
10G for 20ms once on each X, Y and Z axis
SAFETY
SAFETY APPROVED
-
EMI & EMS
-